← All tenders

195079 — Southern Cross Uni PC2 Laboratory | Abacorp

Status: new · 48 files · 68 extracted items

View tender on EstimateOne →

Builders (1)

CompanyContactPhoneEmail
AbacorpOliver Kuk02 7209 4245oliver.kuk@abacorp.com.au

Contacts (27)

2CREATE Architecture Pty LtdCollaborating Architect2CREATE Architecture Pty Ltd10.50
Anthony ButlerAJM Aircon10.80
BKA ArchitectureArchitectBKA Architecturebka@bka.com.au(02) 9318 920010.90
Clarence ConsultantsClarence Consultantsmail@clarenceconsultants.com.au02 6652 485510.70
Clarence Consultants Pty LtdEngineer (Consulting Engineers, Electrical and Mechanical)Clarence Consultants Pty Ltdmail@clarenceconsultants.com.au02 6652 485510.85
Competent Fire Safety ProfessionalsFire Detection & EWISCompetent Fire Safety Professionalsadmin@cfspnsw.com.au02 6624 700710.75
Coulter Advisory Pty LtdLaboratory compliance and certification advisorCoulter Advisory Pty Ltd40.30
Danika HeadClient ContactSouthern Cross Universitydanika.head@scu.edu.au02 6620 378950.95
Dave BaskervilleContact, incumbent SCU Security ContractorAutomated Protection Systemsadmin@automatedprotection.com.au0416 242 00870.90
Derrick ChuBKA Architecture10.80
ENV SolutionsHazardous materials survey consultantENV Solutions480.30
Glenn HaigHydraulic ServicesGlenn Haig and PartnersGlenn@Glennhaig.com.au02 6658 244450.95
Glenn Haig PartnersHydraulic + Fire ConsultantsGlenn Haig Partners10.40
Glenn Haigh & PartnersHydraulic and fire services consultant (copyright and design owner of the drawing)Glenn Haigh & Partners10.45
Glenn Haigh PartnersHydraulic + Fire ConsultantsGlenn Haigh Partners10.45
Grant GordonClient – FacilitiesSCU Facilities ManagementGrant.gordon@scu.edu.au0408 318 78950.95
Hydraulic + Fire ConsultantsHydraulic and fire services consultantHydraulic + Fire Consultants10.45
John BakerArchitectBKA Architecturejb@bka.com.au(02) 9318 920050.95
John RaynerSpecificationJohn Rayner Architecturejohn@johnraynerarchitecture.com.au0415 104 83050.95
johnrayner architectureSpecification author (copyright owner)johnrayner architecture20.35
Ken HeardElectrical ServicesClarence ConsultantsKen@Clarenceconsultants.com.au02 6652 485550.95
Matt KarpikMechanical ServicesClarence ConsultantsMatt@Clarenceconsultants.com.au02 6652 485550.95
Michael BakerStructural EngineerLucena Engineeringmichael@lucena.com.au6687 818250.85
Silvina MedelArchitectBKA Architecturesilvina.m@bka.com.au(02) 6687 271250.95
Slivina MedelBKA Architecture10.80
Suzy RundleBKA Architecture10.80
VideoproVideopro(07) 3250 000010.45

BOM — from schedules (41)

-20 deg freezer1ea—10.50
-20 freezer1ea—10.65
-80 deg freezer-80 deg. Freezer1ea—10.60
-80 freezerUltra-low temperature freezer1ea—10.65
acoustic ceiling panel (type A)Selected Acoustic Panel, size A per legend. This is a ceiling reflected plan (RCP), so the items are ceiling panels, not furniture.28ea1200 x 1200—10.75
acoustic ceiling panel (type B)Selected Acoustic Panel, size B per legend. This is a ceiling reflected plan (RCP), so the items are ceiling panels, not furniture.10ea2400 x 1200—10.80
autoclaveAutoclave1ea—10.60
autoclave1ea—10.55
AV cabinetAV cabinet1ea—10.50
bin2ea—10.60
biological safety cabinetBiological Safety Cabinet1ea—10.55
cabinet/storage unit1ea—10.40
custom joineryCustom joinery (legend: JNx)1ea—10.60
custom joineryCustom joinery (legend: JNx)3ea—10.55
custom joineryCustom joinery (legend: JNx)4ea—10.75
deskDesk (legend: DSK)10ea—10.55
distribution board1ea—10.50
eyewash1ea—10.60
fire extinguisher1ea—10.40
fridgeFridge1ea—10.60
fume cupboardFume Cupboard1ea—10.60
fume cupboardFume cupboard with fume cupboard base1ea—10.60
future fume cupboardFUTURE FUME CUPB.1ea—10.50
glass dishwasherGlass Dishwasher1ea—10.55
glassware dishwasher1ea—10.55
hand basin1ea—10.60
hot water unitHot Water Unit2ea—10.60
incubatorTag partially legible1ea—10.40
lab desk / bench (DSK1)Base unit under island bench pair4ea—10.60
lab desk / bench (DSK2)Island benches and perimeter bench desks4ea—10.55
laboratory deskDesk (legend: DSK)34ea—10.60
lockersLocker banks labelled 28 LOCKERS (x2) and 16 LOCKERS3ea—10.50
refrigerator1ea—10.60
safety showerSafety shower connected through ceiling space1ea—10.70
shelving unit1ea—10.40
storage unit1ea—10.40
televisionTelevision5ea—10.50
televisionTelevision1ea—10.60
trolleyTrolley10ea—10.70
trolley2ea—10.60
wireless access point (WAP)Marked 'WAP' on the plan5ea—10.50
Total (valued lines)—

Feedback loop

✓ = correct · ✗ = delete (wrong) · 🚩 = flag with a note. Everything lands in the corrections log.
  • Clarence Consultants (Clarence Consultants)Contact · p.1
    mail@clarenceconsultants.com.au · 02 6652 4855
  • Slivina Medel (BKA Architecture)Contact · p.1
  • Suzy Rundle (BKA Architecture)Contact · p.1
  • Derrick Chu (BKA Architecture)Contact · p.1
  • Anthony Butler (AJM Aircon)Contact · p.1
  • Dave Baskerville — Contact, incumbent SCU Security Contractor (Automated Protection Systems)Contact · p.7
    admin@automatedprotection.com.au · 0416 242 008
  • Clarence Consultants Pty Ltd — Engineer (Consulting Engineers, Electrical and Mechanical) (Clarence Consultants Pty Ltd)Contact · p.1
    mail@clarenceconsultants.com.au · 02 6652 4855
  • Videopro (Videopro)Contact · p.1
    (07) 3250 0000
  • Competent Fire Safety Professionals — Fire Detection & EWIS (Competent Fire Safety Professionals)Contact · p.1
    admin@cfspnsw.com.au · 02 6624 7007
  • Danika Head — Client Contact (Southern Cross University)Contact · p.5
    danika.head@scu.edu.au · 02 6620 3789
  • Grant Gordon — Client – Facilities (SCU Facilities Management)Contact · p.5
    Grant.gordon@scu.edu.au · 0408 318 789
  • John Baker — Architect (BKA Architecture)Contact · p.5
    jb@bka.com.au · (02) 9318 9200
  • Silvina Medel — Architect (BKA Architecture)Contact · p.5
    silvina.m@bka.com.au · (02) 6687 2712
  • Ken Heard — Electrical Services (Clarence Consultants)Contact · p.5
    Ken@Clarenceconsultants.com.au · 02 6652 4855
  • Matt Karpik — Mechanical Services (Clarence Consultants)Contact · p.5
    Matt@Clarenceconsultants.com.au · 02 6652 4855
  • Glenn Haig — Hydraulic Services (Glenn Haig and Partners)Contact · p.5
    Glenn@Glennhaig.com.au · 02 6658 2444
  • John Rayner — Specification (John Rayner Architecture)Contact · p.5
    john@johnraynerarchitecture.com.au · 0415 104 830
  • Michael Baker — Structural Engineer (Lucena Engineering)Contact · p.5
    michael@lucena.com.au · 6687 8182
  • Glenn Haig Partners — Hydraulic + Fire Consultants (Glenn Haig Partners)Contact · p.1
  • Glenn Haigh & Partners — Hydraulic and fire services consultant (copyright and design owner of the drawing) (Glenn Haigh & Partners)Contact · p.1
  • Glenn Haigh Partners — Hydraulic + Fire Consultants (Glenn Haigh Partners)Contact · p.1
  • Hydraulic + Fire Consultants — Hydraulic and fire services consultant (Hydraulic + Fire Consultants)Contact · p.1
  • BKA Architecture — Architect (BKA Architecture)Contact · p.1
    bka@bka.com.au · (02) 9318 9200
  • 2CREATE Architecture Pty Ltd — Collaborating Architect (2CREATE Architecture Pty Ltd)Contact · p.1
  • johnrayner architecture — Specification author (copyright owner) (johnrayner architecture)Contact · p.2
  • Coulter Advisory Pty Ltd — Laboratory compliance and certification advisor (Coulter Advisory Pty Ltd)Contact · p.4
  • ENV Solutions — Hazardous materials survey consultant (ENV Solutions)Contact · p.48
  • laboratory desk — Desk (legend: DSK)BOM · p.1
    qty 34 ea
  • desk — Desk (legend: DSK)BOM · p.1
    qty 10 ea
  • custom joinery — Custom joinery (legend: JNx)BOM · p.1
    qty 1 ea
  • custom joinery — Custom joinery (legend: JNx)BOM · p.1
    qty 3 ea
  • custom joinery — Custom joinery (legend: JNx)BOM · p.1
    qty 4 ea
  • trolley — TrolleyBOM · p.1
    qty 10 ea
  • television — TelevisionBOM · p.1
    qty 5 ea
  • television — TelevisionBOM · p.1
    qty 1 ea
  • hot water unit — Hot Water UnitBOM · p.1
    qty 2 ea
  • binBOM · p.1
    qty 2 ea
  • lockers — Locker banks labelled 28 LOCKERS (x2) and 16 LOCKERSBOM · p.1
    qty 3 ea
  • autoclave — AutoclaveBOM · p.1
    qty 1 ea
  • fume cupboard — Fume CupboardBOM · p.1
    qty 1 ea
  • glass dishwasher — Glass DishwasherBOM · p.1
    qty 1 ea
  • fridge — FridgeBOM · p.1
    qty 1 ea
  • -80 deg freezer — -80 deg. FreezerBOM · p.1
    qty 1 ea
  • -20 deg freezerBOM · p.1
    qty 1 ea
  • biological safety cabinet — Biological Safety CabinetBOM · p.1
    qty 1 ea
  • cabinet/storage unitBOM · p.1
    qty 1 ea
  • storage unitBOM · p.1
    qty 1 ea
  • shelving unitBOM · p.1
    qty 1 ea
  • future fume cupboard — FUTURE FUME CUPB.BOM · p.1
    qty 1 ea
  • AV cabinet — AV cabinetBOM · p.1
    qty 1 ea
  • acoustic ceiling panel (type A) — Selected Acoustic Panel, size A per legend. This is a ceiling reflected plan (RCP), so the items are ceiling panels, not furniture.BOM · p.1
    qty 28 ea · 1200 x 1200
  • acoustic ceiling panel (type B) — Selected Acoustic Panel, size B per legend. This is a ceiling reflected plan (RCP), so the items are ceiling panels, not furniture.BOM · p.1
    qty 10 ea · 2400 x 1200
  • wireless access point (WAP) — Marked 'WAP' on the planBOM · p.1
    qty 5 ea
  • lab desk / bench (DSK1) — Base unit under island bench pairBOM · p.1
    qty 4 ea
  • lab desk / bench (DSK2) — Island benches and perimeter bench desksBOM · p.1
    qty 4 ea
  • trolleyBOM · p.1
    qty 2 ea
  • fume cupboard — Fume cupboard with fume cupboard baseBOM · p.1
    qty 1 ea
  • -80 freezer — Ultra-low temperature freezerBOM · p.1
    qty 1 ea
  • -20 freezerBOM · p.1
    qty 1 ea
  • refrigeratorBOM · p.1
    qty 1 ea
  • distribution boardBOM · p.1
    qty 1 ea
  • safety shower — Safety shower connected through ceiling spaceBOM · p.1
    qty 1 ea
  • eyewashBOM · p.1
    qty 1 ea
  • hand basinBOM · p.1
    qty 1 ea
  • glassware dishwasherBOM · p.1
    qty 1 ea
  • autoclaveBOM · p.1
    qty 1 ea
  • incubator — Tag partially legibleBOM · p.1
    qty 1 ea
  • fire extinguisherBOM · p.1
    qty 1 ea