← All tenders
195079 — Southern Cross Uni PC2 Laboratory | Abacorp
Status: new · 48 files · 68 extracted items
Builders (1)
| Company | Contact | Phone | |
|---|---|---|---|
| Abacorp | Oliver Kuk | 02 7209 4245 | oliver.kuk@abacorp.com.au |
Contacts (27)
| 2CREATE Architecture Pty Ltd | Collaborating Architect | 2CREATE Architecture Pty Ltd | 1 | 0.50 | ||
| Anthony Butler | AJM Aircon | 1 | 0.80 | |||
| BKA Architecture | Architect | BKA Architecture | bka@bka.com.au | (02) 9318 9200 | 1 | 0.90 |
| Clarence Consultants | Clarence Consultants | mail@clarenceconsultants.com.au | 02 6652 4855 | 1 | 0.70 | |
| Clarence Consultants Pty Ltd | Engineer (Consulting Engineers, Electrical and Mechanical) | Clarence Consultants Pty Ltd | mail@clarenceconsultants.com.au | 02 6652 4855 | 1 | 0.85 |
| Competent Fire Safety Professionals | Fire Detection & EWIS | Competent Fire Safety Professionals | admin@cfspnsw.com.au | 02 6624 7007 | 1 | 0.75 |
| Coulter Advisory Pty Ltd | Laboratory compliance and certification advisor | Coulter Advisory Pty Ltd | 4 | 0.30 | ||
| Danika Head | Client Contact | Southern Cross University | danika.head@scu.edu.au | 02 6620 3789 | 5 | 0.95 |
| Dave Baskerville | Contact, incumbent SCU Security Contractor | Automated Protection Systems | admin@automatedprotection.com.au | 0416 242 008 | 7 | 0.90 |
| Derrick Chu | BKA Architecture | 1 | 0.80 | |||
| ENV Solutions | Hazardous materials survey consultant | ENV Solutions | 48 | 0.30 | ||
| Glenn Haig | Hydraulic Services | Glenn Haig and Partners | Glenn@Glennhaig.com.au | 02 6658 2444 | 5 | 0.95 |
| Glenn Haig Partners | Hydraulic + Fire Consultants | Glenn Haig Partners | 1 | 0.40 | ||
| Glenn Haigh & Partners | Hydraulic and fire services consultant (copyright and design owner of the drawing) | Glenn Haigh & Partners | 1 | 0.45 | ||
| Glenn Haigh Partners | Hydraulic + Fire Consultants | Glenn Haigh Partners | 1 | 0.45 | ||
| Grant Gordon | Client – Facilities | SCU Facilities Management | Grant.gordon@scu.edu.au | 0408 318 789 | 5 | 0.95 |
| Hydraulic + Fire Consultants | Hydraulic and fire services consultant | Hydraulic + Fire Consultants | 1 | 0.45 | ||
| John Baker | Architect | BKA Architecture | jb@bka.com.au | (02) 9318 9200 | 5 | 0.95 |
| John Rayner | Specification | John Rayner Architecture | john@johnraynerarchitecture.com.au | 0415 104 830 | 5 | 0.95 |
| johnrayner architecture | Specification author (copyright owner) | johnrayner architecture | 2 | 0.35 | ||
| Ken Heard | Electrical Services | Clarence Consultants | Ken@Clarenceconsultants.com.au | 02 6652 4855 | 5 | 0.95 |
| Matt Karpik | Mechanical Services | Clarence Consultants | Matt@Clarenceconsultants.com.au | 02 6652 4855 | 5 | 0.95 |
| Michael Baker | Structural Engineer | Lucena Engineering | michael@lucena.com.au | 6687 8182 | 5 | 0.85 |
| Silvina Medel | Architect | BKA Architecture | silvina.m@bka.com.au | (02) 6687 2712 | 5 | 0.95 |
| Slivina Medel | BKA Architecture | 1 | 0.80 | |||
| Suzy Rundle | BKA Architecture | 1 | 0.80 | |||
| Videopro | Videopro | (07) 3250 0000 | 1 | 0.45 |
BOM — from schedules (41)
| -20 deg freezer | 1 | ea | — | 1 | 0.50 | |||
| -20 freezer | 1 | ea | — | 1 | 0.65 | |||
| -80 deg freezer | -80 deg. Freezer | 1 | ea | — | 1 | 0.60 | ||
| -80 freezer | Ultra-low temperature freezer | 1 | ea | — | 1 | 0.65 | ||
| acoustic ceiling panel (type A) | Selected Acoustic Panel, size A per legend. This is a ceiling reflected plan (RCP), so the items are ceiling panels, not furniture. | 28 | ea | 1200 x 1200 | — | 1 | 0.75 | |
| acoustic ceiling panel (type B) | Selected Acoustic Panel, size B per legend. This is a ceiling reflected plan (RCP), so the items are ceiling panels, not furniture. | 10 | ea | 2400 x 1200 | — | 1 | 0.80 | |
| autoclave | Autoclave | 1 | ea | — | 1 | 0.60 | ||
| autoclave | 1 | ea | — | 1 | 0.55 | |||
| AV cabinet | AV cabinet | 1 | ea | — | 1 | 0.50 | ||
| bin | 2 | ea | — | 1 | 0.60 | |||
| biological safety cabinet | Biological Safety Cabinet | 1 | ea | — | 1 | 0.55 | ||
| cabinet/storage unit | 1 | ea | — | 1 | 0.40 | |||
| custom joinery | Custom joinery (legend: JNx) | 1 | ea | — | 1 | 0.60 | ||
| custom joinery | Custom joinery (legend: JNx) | 3 | ea | — | 1 | 0.55 | ||
| custom joinery | Custom joinery (legend: JNx) | 4 | ea | — | 1 | 0.75 | ||
| desk | Desk (legend: DSK) | 10 | ea | — | 1 | 0.55 | ||
| distribution board | 1 | ea | — | 1 | 0.50 | |||
| eyewash | 1 | ea | — | 1 | 0.60 | |||
| fire extinguisher | 1 | ea | — | 1 | 0.40 | |||
| fridge | Fridge | 1 | ea | — | 1 | 0.60 | ||
| fume cupboard | Fume Cupboard | 1 | ea | — | 1 | 0.60 | ||
| fume cupboard | Fume cupboard with fume cupboard base | 1 | ea | — | 1 | 0.60 | ||
| future fume cupboard | FUTURE FUME CUPB. | 1 | ea | — | 1 | 0.50 | ||
| glass dishwasher | Glass Dishwasher | 1 | ea | — | 1 | 0.55 | ||
| glassware dishwasher | 1 | ea | — | 1 | 0.55 | |||
| hand basin | 1 | ea | — | 1 | 0.60 | |||
| hot water unit | Hot Water Unit | 2 | ea | — | 1 | 0.60 | ||
| incubator | Tag partially legible | 1 | ea | — | 1 | 0.40 | ||
| lab desk / bench (DSK1) | Base unit under island bench pair | 4 | ea | — | 1 | 0.60 | ||
| lab desk / bench (DSK2) | Island benches and perimeter bench desks | 4 | ea | — | 1 | 0.55 | ||
| laboratory desk | Desk (legend: DSK) | 34 | ea | — | 1 | 0.60 | ||
| lockers | Locker banks labelled 28 LOCKERS (x2) and 16 LOCKERS | 3 | ea | — | 1 | 0.50 | ||
| refrigerator | 1 | ea | — | 1 | 0.60 | |||
| safety shower | Safety shower connected through ceiling space | 1 | ea | — | 1 | 0.70 | ||
| shelving unit | 1 | ea | — | 1 | 0.40 | |||
| storage unit | 1 | ea | — | 1 | 0.40 | |||
| television | Television | 5 | ea | — | 1 | 0.50 | ||
| television | Television | 1 | ea | — | 1 | 0.60 | ||
| trolley | Trolley | 10 | ea | — | 1 | 0.70 | ||
| trolley | 2 | ea | — | 1 | 0.60 | |||
| wireless access point (WAP) | Marked 'WAP' on the plan | 5 | ea | — | 1 | 0.50 | ||
| Total (valued lines) | — | |||||||
Feedback loop
✓ = correct · ✗ = delete (wrong) · 🚩 = flag with a note. Everything lands in the corrections log.
- Clarence Consultants (Clarence Consultants)Contact · p.1mail@clarenceconsultants.com.au · 02 6652 4855
- Slivina Medel (BKA Architecture)Contact · p.1
- Suzy Rundle (BKA Architecture)Contact · p.1
- Derrick Chu (BKA Architecture)Contact · p.1
- Anthony Butler (AJM Aircon)Contact · p.1
- Dave Baskerville — Contact, incumbent SCU Security Contractor (Automated Protection Systems)Contact · p.7admin@automatedprotection.com.au · 0416 242 008
- Clarence Consultants Pty Ltd — Engineer (Consulting Engineers, Electrical and Mechanical) (Clarence Consultants Pty Ltd)Contact · p.1mail@clarenceconsultants.com.au · 02 6652 4855
- Videopro (Videopro)Contact · p.1(07) 3250 0000
- Competent Fire Safety Professionals — Fire Detection & EWIS (Competent Fire Safety Professionals)Contact · p.1admin@cfspnsw.com.au · 02 6624 7007
- Danika Head — Client Contact (Southern Cross University)Contact · p.5danika.head@scu.edu.au · 02 6620 3789
- Grant Gordon — Client – Facilities (SCU Facilities Management)Contact · p.5Grant.gordon@scu.edu.au · 0408 318 789
- John Baker — Architect (BKA Architecture)Contact · p.5jb@bka.com.au · (02) 9318 9200
- Silvina Medel — Architect (BKA Architecture)Contact · p.5silvina.m@bka.com.au · (02) 6687 2712
- Ken Heard — Electrical Services (Clarence Consultants)Contact · p.5Ken@Clarenceconsultants.com.au · 02 6652 4855
- Matt Karpik — Mechanical Services (Clarence Consultants)Contact · p.5Matt@Clarenceconsultants.com.au · 02 6652 4855
- Glenn Haig — Hydraulic Services (Glenn Haig and Partners)Contact · p.5Glenn@Glennhaig.com.au · 02 6658 2444
- John Rayner — Specification (John Rayner Architecture)Contact · p.5john@johnraynerarchitecture.com.au · 0415 104 830
- Michael Baker — Structural Engineer (Lucena Engineering)Contact · p.5michael@lucena.com.au · 6687 8182
- Glenn Haig Partners — Hydraulic + Fire Consultants (Glenn Haig Partners)Contact · p.1
- Glenn Haigh & Partners — Hydraulic and fire services consultant (copyright and design owner of the drawing) (Glenn Haigh & Partners)Contact · p.1
- Glenn Haigh Partners — Hydraulic + Fire Consultants (Glenn Haigh Partners)Contact · p.1
- Hydraulic + Fire Consultants — Hydraulic and fire services consultant (Hydraulic + Fire Consultants)Contact · p.1
- BKA Architecture — Architect (BKA Architecture)Contact · p.1bka@bka.com.au · (02) 9318 9200
- 2CREATE Architecture Pty Ltd — Collaborating Architect (2CREATE Architecture Pty Ltd)Contact · p.1
- johnrayner architecture — Specification author (copyright owner) (johnrayner architecture)Contact · p.2
- Coulter Advisory Pty Ltd — Laboratory compliance and certification advisor (Coulter Advisory Pty Ltd)Contact · p.4
- ENV Solutions — Hazardous materials survey consultant (ENV Solutions)Contact · p.48
- laboratory desk — Desk (legend: DSK)BOM · p.1qty 34 ea
- desk — Desk (legend: DSK)BOM · p.1qty 10 ea
- custom joinery — Custom joinery (legend: JNx)BOM · p.1qty 1 ea
- custom joinery — Custom joinery (legend: JNx)BOM · p.1qty 3 ea
- custom joinery — Custom joinery (legend: JNx)BOM · p.1qty 4 ea
- trolley — TrolleyBOM · p.1qty 10 ea
- television — TelevisionBOM · p.1qty 5 ea
- television — TelevisionBOM · p.1qty 1 ea
- hot water unit — Hot Water UnitBOM · p.1qty 2 ea
- binBOM · p.1qty 2 ea
- lockers — Locker banks labelled 28 LOCKERS (x2) and 16 LOCKERSBOM · p.1qty 3 ea
- autoclave — AutoclaveBOM · p.1qty 1 ea
- fume cupboard — Fume CupboardBOM · p.1qty 1 ea
- glass dishwasher — Glass DishwasherBOM · p.1qty 1 ea
- fridge — FridgeBOM · p.1qty 1 ea
- -80 deg freezer — -80 deg. FreezerBOM · p.1qty 1 ea
- -20 deg freezerBOM · p.1qty 1 ea
- biological safety cabinet — Biological Safety CabinetBOM · p.1qty 1 ea
- cabinet/storage unitBOM · p.1qty 1 ea
- storage unitBOM · p.1qty 1 ea
- shelving unitBOM · p.1qty 1 ea
- future fume cupboard — FUTURE FUME CUPB.BOM · p.1qty 1 ea
- AV cabinet — AV cabinetBOM · p.1qty 1 ea
- acoustic ceiling panel (type A) — Selected Acoustic Panel, size A per legend. This is a ceiling reflected plan (RCP), so the items are ceiling panels, not furniture.BOM · p.1qty 28 ea · 1200 x 1200
- acoustic ceiling panel (type B) — Selected Acoustic Panel, size B per legend. This is a ceiling reflected plan (RCP), so the items are ceiling panels, not furniture.BOM · p.1qty 10 ea · 2400 x 1200
- wireless access point (WAP) — Marked 'WAP' on the planBOM · p.1qty 5 ea
- lab desk / bench (DSK1) — Base unit under island bench pairBOM · p.1qty 4 ea
- lab desk / bench (DSK2) — Island benches and perimeter bench desksBOM · p.1qty 4 ea
- trolleyBOM · p.1qty 2 ea
- fume cupboard — Fume cupboard with fume cupboard baseBOM · p.1qty 1 ea
- -80 freezer — Ultra-low temperature freezerBOM · p.1qty 1 ea
- -20 freezerBOM · p.1qty 1 ea
- refrigeratorBOM · p.1qty 1 ea
- distribution boardBOM · p.1qty 1 ea
- safety shower — Safety shower connected through ceiling spaceBOM · p.1qty 1 ea
- eyewashBOM · p.1qty 1 ea
- hand basinBOM · p.1qty 1 ea
- glassware dishwasherBOM · p.1qty 1 ea
- autoclaveBOM · p.1qty 1 ea
- incubator — Tag partially legibleBOM · p.1qty 1 ea
- fire extinguisherBOM · p.1qty 1 ea